TAQU T20 Duct Temperature and Humidity Sensors Transmitter RS485 0-10V 0-5V 4-20mA Duct type for HVAC System TAQU T20 Duct Temperature and Humidity Sensors Transmitter RS485 0-10V 0-5V 4-20mA Duct type for HVAC System TAQU T20 Duct Temperature and Humidity Sensors Transmitter RS485 0-10V 0-5V 4-20mA Duct type for HVAC System TAQU T20 Duct Temperature and Humidity Sensors Transmitter RS485 0-10V 0-5V 4-20mA Duct type for HVAC System TAQU T20 Duct Temperature and Humidity Sensors Transmitter RS485 0-10V 0-5V 4-20mA Duct type for HVAC System

TAQU T20 Duct Temperature and Humidity Sensors Transmitter RS485 0-10V 0-5V 4-20mA Duct type for HVAC System

Price:
 Open price  
Min.Order Quantity:
1 Piece
Supply Ability:
1000 Piece per Day
Port:
Shenzhen
Place of Origin:
China
Payment Terms:
T/T, PayPal
Brand:
TAQU
Products Model:
T20
Share:
  • Products Details

Quick Details

  • Brand Name: TAQU

    Model Number: T20

    Place of Origin: China

Packaging & Delivery

  • Packaging Details: box
  • Delivery Detail: 7-15

Specifications

Summary

T20 series air duct temperature and humidity sensors are specially designed for various intelligent buildings and HVAC systems.The product adopts a high performance built-in linear processor with 4-20mA, 0-10VDC and 485 output signals. The pipeline type is equipped with PC tube probe and built-in polymer filter head. It can guarantee the measuring accuracy and prolong the service life of the sensor in the humid and dusty environment, and can meet the measuring requirements of different measuring environments and various high precision and high stability.

 

Features

-High Precision Temperature and Humidity Sensor

-Advanced circuit design, high measurement accuracy

-Stable performance and good linearity

-Easy installation and high cost performance

-The protective head is made of macro-molecule material with good air permeability.

-Multiple output modes are optional

-Sensor factory standard calibration/high humidity calibration

 

Application

-HVAC

-Electronic factory building

-Environmental Monitoring in Computer Room

-Power Environment Monitoring

-Agricultural Environmental Monitoring

-Meteorological Environmental Monitoring

-Environmental monitoring of bio-pharmaceuticals

-Airports, subway stations, hotels, museums, gymnasiums, etc.

 

 

Parameter

Temperature

Accuracy:

Range:

Stabilization Time:

Calibration:

±0.2±0.3±0.5±1

050080-560 Refer to the Selection Table

2-5mins

Standard calibration

Humidity

Accuracy:

Range:

Stabilization Time:

Calibration:

±2%RH±3%RH±5%RH

0100%RH

2-5mins

Standard calibration / high humidity calibration

Output parameter

Signal output:

Current-mode  24VDC±10%

Voltage-mode  24VDC/AC±10%

RS485  1028VDC

485 Parameter

Signal type:

RS485 type:

Connect:

Address:

Protocol:

Data Format:

Baud Rate:

 

RS485 Serial Port Output

Multipoint, Half Duplex

2Wire system, maximum communication distance 1200 meters, terminal direct connection

1-254 Through the switch/software settings, the broadcast address is: 0, and the default address is: 1

MODBUS

1Start bits, 8 data bits, no parity, 2 termination bits

1200 bit/s, 2400 bit/s, 4800 bit/s, 9600 bit/s, 19200 bit/s, 28800 bit/s, 38400 bit/s, through the switch/software settings, the default value is 9600 bit/s.

Power

Power supply:

Current-mode  24VDC±10%

Voltage-mode  24VDC/AC±10%

RS485  1028VDC

Connection mode

Terminal:

Cable Specifications:

5.0mm spacing, M3 steel screw, 0.2Nm torque, 0.02 ohmic contact resistance

2418AWG0.21.0mm2),stripping length 6-7mm

Environment

Working environment:

Temperature  -2080℃  probe up to100℃

Humidity  099%RHno condensation

Storage environment:

Temperature  -3080

Humidity  095%RHno condensation

Protection level

Shell:

Fire Grade:

EMC:

IP65   Reference IEC 529 – 598/GB 700 – 86/ GB 4208

V-0    ReferenceUL94

Reference GB/T 13926EN61000-6-2EN61000-6-3  

Material and color

Shell:

Probe material:

Probe length:

Weight:

ABS (light blue)

PC polycarbonate

150/200/270mm, customizable

Appr. 140 g (total weight)

 

Ordering Information

Series

Type of measurement

Temperature measurement range

Accuracy of temperature measurement

T20-

Humidity

Temperature and Humidity

 

(RH)

(TH)

 

 

050

080

0100

-560

-2080

-4080

-1050

030

(T1)

(T2)

(T3)

(T4)

(T5)

(T6)

(T13)

(T14)

±0.2

±0.3

±0.5

±1

 

(B)

(C)

(D)

(E)

 

 

Humidity measurement range

Precision of humidity measurement

signal output

Probe length

0100%RH

095%RH

1090%RH

2080%RH

099%RH

(H1)

(H2)

(H3)

(H4)

(H5)

±2%RH

±3%RH

±5%RH

 

(B)

(C)

(D)

 

420mA  2-wire

420mA  3-wire

05VDC

010VDC

RS485 output

(2)

(3)

(4)

(5)

(RS)

150mm

200mm

270mm

custom

T15

T20

T27

UD

 
  • Email to this supplier
  • To :
    Jerry Zhang  |  Taqu Sensor Technologies Co.,Ltd
  • *Subject :
  • Quantity Order:
  • *Message :

  • Your message must be between 20-2000 characters
  •  Please enter your company name:

    Please make sure your company name is entered correctly.

  • * Please enter your email address:

    Please make sure your email address is entered correctly.

  • * Please enter your mobile phone:

    Please make sure your mobile phone is entered correctly.

Verified Supplier - Taqu Sensor Technologies Co.,Ltd Bussiness Type:  Manufacturer
Scale:  11 - 50 People
Country/Region:  China (Mainland)/Asia
Established: