Taqu T10 Display Indoor Temperature and Humidity Sensors Transmitters RS485 4-20mA 0-10VDC Accuracy for HVAC system
- Products Details
Quick Details
-
Brand Name: TAQU
Model Number: T10D
Place of Origin: China
Packaging & Delivery
- Packaging Details: box
- Delivery Detail: 7-15
Specifications
Summary
T10 series indoor temperature and humidity sensors adopt high quality temperature and humidity sensor components, which are suitable for various intelligent building environment monitoring, HVAC system.The product has simple shape and structure, direct connection of terminals and convenient installation.The products adopt high-performance built-in microprocessor and high-precision sensors, which can meet the requirements of various environmental temperature and humidity measurements as well as various high-precision and high-stability measurements.
Indoor temperature and humidity sensor has current, voltage, 485 output, resistance output and other signals optional, 485 serial port output, using MODBUS communication protocol.The T10 series has two designs, with or without LCD display.Usually used in HVAC electronic workshop, engine room environment monitoring, power environment monitoring, agricultural environment monitoring, meteorological environment monitoring, biopharmaceutical environment monitoring, airports, subway stations, hotels, museums, gymnasiums and other places.
Features
-High Precision Temperature and Humidity Sensor
-Applicable to all kinds of intelligent building environment monitoring, HVAC system
-Advanced circuit design, high measurement accuracy, stable performance
-Simple appearance, easy installation, high cost performance
-There are many kinds of output modes. It can be displayed on a pen-end LCD screen.
-Sensor factory standard calibration/high humidity calibration
Application
-HVAC
-Electronic factory building
-Environmental Monitoring in Computer Room
-Power Environment Monitoring
-Agricultural Environmental Monitoring
-Meteorological Environmental Monitoring
-Environmental monitoring of biopharmaceuticals
-Airports, subway stations, hotels, museums, gymnasiums, etc.
Parameter
Temperature |
Accuracy: Range: Stabilization Time: Calibration: |
±0.2℃、±0.3℃、±0.5℃、±1℃ 0~50℃、0~80℃、-5~60℃ Refer to the Selection Table 2-5mins Standard calibration |
Humidity |
Accuracy: Range: Stabilization Time: Calibration: |
±2%RH、±3%RH、±5%RH 0~100%RH 2-5mins Standard calibration / high humidity calibration |
Output parameter |
Signal output: |
4~20mA RL<400 ohm RS485 Refer to the Selection Table for details. |
485 Parameter |
Signal type: RS485 type: Connect: Address: Protocol: Data Format: Baud Rate: |
RS485 Serial Port Output Multipoint, Half Duplex 2Wire system, maximum communication distance 1200 meters, terminal direct connection 1-254 Through the switch/software settings, the broadcast address is: 0, and the default address is: 1 MODBUS 1Start bits, 8 data bits, no parity, 2 termination bits 1200 bit/s, 2400 bit/s, 4800 bit/s, 9600 bit/s, 19200 bit/s, 28800 bit/s, 38400 bit/s, through the switch/software settings, the default value is 9600 bit/s. |
Power |
Power supply: |
Current-mode 24VDC±10% Voltage-mode 24VDC/AC±10% RS485 10~28VDC |
Key Function |
MENU : ▲ : ▼ : ENTER: |
Press to enter or quit the setting mode Setting Mode:UP flip and add value. Setting Mode:DOWN flip and decrease value. ENTER to confirm the setting value. |
Connection mode |
Terminal: Cable specifications: |
5.0mm spacing, M2.5 steel screw, 0.2Nm torque, 0.02 ohmic contact resistance. 24~18AWG(0.2~1.0mm2) ,stripping length 6-7mm |
Environment |
Working environment: |
Temperature -20~80℃ probe up to100℃ Humidity 0~99%RH,no condensation |
Storage environment: |
Temperature -30~80℃ Humidity 0~95%RH,no condensation |
|
Protection level |
Shell: Fire Grade: EMC: |
IP65 Reference IEC 529 – 598/GB 700 – 86/ GB 4208 V-0 ReferenceUL94 Reference GB/T 13926,EN61000-6-2,EN61000-6-3 |
Material and Color |
Shell: Panel: Weight: |
ABS (white) PMMA Appr. 110 g (total weight) |
Ordering Information
Series |
Type of measurement |
Temperature measurement range |
Accuracy |
|||
T10- |
Humidity Temperature and humidity Temperature and humidity + dew point temperature |
(RH) (TH) (THD) |
0~50℃ 0~80℃ -5~60℃ -20~80℃ -40~80℃ -10~50℃ -30~70℃ Custom |
(T1) (T2) (T4) (T5) (T6) (T13) (T20) (UD) |
±0.3℃ ±0.5℃ ±1℃ |
(C) (D) (E) |
Humidity measurement range |
Accuracy |
Dew point temperature range |
Signal output |
||||
0~100%RH 0~95%RH 10~90%RH 20~80%RH 0~99%RH |
(H1) (H2) (H3) (H4) (H5) |
±3%RH ±5%RH |
(C) (D) |
-20~40℃ -20~60℃ |
(T15) (T16) |
4~20mA 2-wire 4~20mA3-wire 0~5VDC 0~10VDC RS485 Output |
(2) (3) (4) (5) (RS) |
Additional item |
|
LCD display |
(D) |