Brand Name: TAQU
Model Number: T18
Place of Origin: China
Packaging & Delivery
- Packaging Details: box
- Delivery Detail: 7-15
Specifications
Summary
T18 series carbon dioxide sensors are used in the detection and control of CO2 concentration to monitor ventilation system, effectively reduce energy consumption, and meet the relevant building ventilation, energy saving and related standards. In garage or motor vehicle maintenance and operation workshop, the ventilation system should be started and stopped according to the use situation, or the ventilation system should be automatically operated according to CO2 concentration.
T18 series carbon dioxide sensors can be used in various intelligent buildings and HVAC systems, such as airports, stations, subway stations, pharmaceutical factories, museums, intelligent buildings and gymnasiums.The product adopts infrared principle gas sensor, and has a variety of output signals, which can meet the requirements of different measuring environments and various high precision and high stability measurement.
Features
-High Precision Infrared Carbon Dioxide Sensor
-Automatic Protection Function against High Concentration Gas Shock
-Applicable to all kinds of intelligent building environment monitoring, HVAC system
-Advanced circuit design, high measurement accuracy, stable performance
-Lightweight housing, easy to install on site
-Independent chamber structure, fast response
-Calibration of Sensor Exit Standard
Application
-Electronic factory building
-Environmental Monitoring in Computer Room
-Power Environment Monitoring
-Agricultural Environmental Monitoring
-Meteorological Environmental Monitoring
-Environmental monitoring of biopharmaceuticals
-Airports, subway stations, hotels, museums, gymnasiums, etc.
Parameter
CO2 |
Sensor Type: Accuracy: Range: Response Time: Calibration: |
Infrared Principle ±(30PPM+3%reading), ±(50PPM+5%reading) 0-5000PPM <10s Standard Calibration |
Output Parameter |
Signal Output: Relay: |
4~20mA RL<400 ohm 0~10VDC RL>10k ohm Relay output can be selected by keys or jumpers 1 x SPST, 1A/30VDC |
485 Parameter |
Signal Type: RS485 Type: Connect: Address: Protocol: Data Format: Baud Rate: |
RS485 Serial Port Output Multipoint, Half Duplex 2Wire system, maximum communication distance 1200 meters, terminal direct connection 1-254 Through the switch/software settings, the broadcast address is: 0, and the default address is: 1 MODBUS 1Start bits, 8 data bits, no parity, 2 termination bits 1200 bit/s, 2400 bit/s, 4800 bit/s, 9600 bit/s, 19200 bit/s, 28800 bit/s, 38400 bit/s, through the switch/software settings, the default value is 9600 bit/s. |
Relay Parameters |
Relay: Threshold Set: Backlash Set: |
3A: 12VAC/24VDC 0~ 1999ppm 10 ppm, 20 ppm, 50 ppm, 100 ppm, 150 ppm, 200 ppm |
Key Function |
MENU: ▲ : ▼ : ENTER: |
Press to enter the setting interface and exit interface Setting mode: flip up and add setting Setting mode: flip down and add setting Determine the set value |
Power |
Power Supply: |
Current-mode 24VDC±10% Voltage-mode 24VDC/AC±10% RS485 10-28VDC |
Connection Mode |
Terminal: Cable Specifications: |
5.0mm spacing, M2.5 steel screw, 0.2Nm torque, 0.02 ohmic contact resistance 24_18AWG (0.2-1.0mm2), stripping length 6-7mm |
Environment |
Working: |
Temperature 0...+50℃ Humidity 0...95%RH, no condensation |
Storage: |
Temperature -20...+70℃ Humidity 0...95%RH, no condensation |
|
Protection Level |
Shell: Fire Grade: EMC: |
IP30 Reference IEC 529-598/GB 700-86/GB 4208 V-0 Reference UL94 Reference GB/T 13926, EN61000-6-2, EN61000-6-3 |
Material and Color |
Shell: Panel: Weight: |
ABS (white) PMMA Appr.150g (Total Weight) |
Order Options
Series |
Range |
Accuracy |
Signal Output |
|||
T18- |
0~2000PPM 0~5000PPM 0~2% 0~5% |
(P1) (P2) (P3) (P4) |
±(30PPM+3%reading) ±(50PPM+5%reading) ±(80PPM+8%reading) |
(C) (D) (E) |
4~20mA 3-Wire 0~5VDC 0~10VDC Relay Output RS485 |
(3) (4) (5) (S) (RS) |
Additional Option |
|
LCD Display |